 CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications
M Series
XM/ZM
UL Recognized CSA Certified VDE Approved
VM
M Series
The M series power entry modules offer the most choices of power entry components and filtering options to fit a specific need. The fully configured M series expands the options of a manufacturer whose products are marketed worldwide. One component, fully assembled and tested, provides the capability of interfacing a multi-voltage power supply to any common voltage or fusing scheme in the world, without modification. *The IEC connector provides an internationally accepted power entry termination, which can be used with a variety of line cords. *The selectable fuseholder allows use of single or dual European fuses, or a single North American fuse. *The optional DPST on/off switch breaks both sides of the line and is labeled with the international I/O markings. *The optional voltage selector provides a convenient means to change transformer primary connection, and it is available in both 2-voltage and 4-voltage configurations. *The series is available with four filter circuits to meet a variety of applications, and convenient connections are provided on unfiltered models to allow wiring of a separate RFI filter. The M series is a family of components offering greater flexibility and cost-effectiveness in the selection of primary power components. Wiring to the modules is accomplished via .110" terminals for labor savings and convenience. Four filter circuits provide a choice of attenuation tailored to specific categories of susceptibility and emissions needs. HM Models - This medical filter provides susceptibility protection without the leakage current associated with line-to-ground capacitors. Designed to allow equipment to meet UL544 for patient care and non-patient care equipment, the HM filter has a maximum leakage current of 2 A at 120 VAC 60 Hz. See Appendix C for more information on medical applications and UL standards. 124
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents.
FM Models - General purpose RFI filter designed for susceptibility applications, effectively providing RFI control of line-to-ground noise. The design is compact and meets the very low leakage current requirements of VDE portable equipment as well as (120 Volt) UL544 non-patient medical equipment. XM Models - High performance RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits. ZM Models - Premium RFI filter designed to bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits.
Fuse Installation Instructions
1. 2. 3. 4. 5. 6. 7.
Remove power cord. Pry door open at socket. Lift and swing door into socket. Lift fuse holder out of housing. Install one (1) AG fuse or two (2) metric fuses*. Replace fuse holder into housing. Swing and snap door back in place.
*Install fuses on one side only, do not install both AG and metric fuses at the same time.
Dimensions are shown for reference purposes only. Specifications subject to change.
USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0
www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
Fuse Options
European Fusing Arrangement**
1. Insert a pocket screwdriver at point "X" as shown. "X"
A
Removing the Fuse Holder
Power Entry Modules
A
Section A-A
North American Fusing Arrangement**
Gently lift UP until the entire door lifts up approximately 1/4" (minimum).
Lift Up
2. Once lifted, the door will pivot on it's hinges and expose the fuse holder.
**Install fuses on one side only. Do Not install both AG and Metric fuses at the same time.
Voltage Selection
To change selected voltage: open cover, using small blade screwdriver or similar tool; set aside cover/fuse block assembly; pull voltage selector card straight out of housing, using indicator pin; orient selector card so that desired voltage is readable at the bottom; orient indicator pin to point up when desired voltage is readable at bottom (note that when indicator pin is fixed, successive voltages are selected by rotating the card 90 clockwise); insert voltage selector card into housing, printed side of card facing forward toward IEC connector and edge containing the desired voltage first; replace cover, and verify that indicator pin shows the desired voltage. Voltage Selector Card Orientation
2
4
3. When the fuse holder is installed in the single fuse position, apply the screwdriver as shown and gently pry up. Use screwdriver as shown, do not use fingers.
When the fuse holder is installed in the dual fuse position, it will normally release as soon as the door is opened.
0
2
0
1
0
0
0
1
2
0
100V
120V
0
1
0
0
10 0
24
0
23
0
0
2
4
0
230V
240V
23
0
1
0
Catalog 1654001 Revised 05-07
Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents.
1 1
2
1
3
2
4 4
23
2
125
Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
Specifications
Maximum leakage current,each line-to-ground HM FM XM/ZM 2A .25 mA .30 mA @ 120 VAC 60 Hz: @ 250 VAC 50 Hz: 5A .50 mA .50 mA Hipot rating (one minute): 1500 VAC line-to-ground: line-to-line 1450 VDC line-to-load (switch off) Unfiltered only 2500 VAC Operating frequency: 50/60 Hz Rated voltage (max.): Operating voltages: Switch: 250 VAC 100, 120, 220/ 240 VAC Double-insulated, rated for 100,000 operations at full load at 70 Amps inrush current. Reversible fuseholder, accepts one 1/4" x 1-1/4" fuse or two 5 x 20 mm fuses .110 [2.79] terminals
Electrical Schematics - Unfiltered Models
VM (1-Voltage)
Power On/Off Note 3
Neutral
K
K
Note 2
120V
Hot
L G
L
Customer Transformer Primaries
VM (2-Voltage)
Power On/Off Note 3 120V
H
240V
A A
120V
B C D
Neutral
K Note 2 Note 1
B C D E
120V
Fuse (not included):
120V
E F
120V
F
Hot
L Note 1
J
F G
Terminals: Minimum insertion loss in dB: Line-to-ground in 50 ohm circuit Current Rating HM 5A FM 05A XM 3A ZM 3A .01 2 15 .05 13 29
Note 4 Customer Transformer Primaries
VM (4-Voltage)
10 22 45 44 40 30
Neutral
Power On/Off Note 3
K
Frequency-MHz .15 .5 1 5 14 14 23 39 18 21 40 46 19 26 46 43 22 40 44 40
120V 100V
230V 240V
A A
20V 100V
H
B C D C D E F
Note 2
Note 1
17 40 44 40
Note 1: Note 2: Note 3: Note 4:
E
120V
Hot
L
J
F G
Note 1
Customer Transformer Primaries
Line-to-line in 50 ohm circuit Current Rating XM 03A ZM 3A Frequency-MHz .02 .03 .05 .07 .15 .5 1 5 13 28 5 37 34 55 5 10 30 40 44
Jumpers required if no input filter is used. Provision for dual European style fusing. On/off switch present only with "S" suffix. When using a center-tapped transformer, the C-F winding should be the low voltage (high current) winding and must be capable of handling the full primary current in the 120V position.
62 68 60 50 75 75 62 54
126
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
Electrical Schematics - Filtered Models
FM & HM (1-Voltage)
Power On/Off
Case Styles - Unfiltered Models
6VM1 (IEC Connector, Selectable Fuseholder)
Neutral
Note 2 Note 1 Note 3
H
B
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
C
D B A
E
Phase
J
F G
Power Entry Modules
6VM1C (IEC Connector, Selectable Fuseholder, Snap-in) FM & HM (4-Voltage)
120V 100V Power On/Off 230V 240V
A K H B C C D E F 120V A 20V 100V
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
C
Neutral
Note 2 Note 1 Note 3
Note 4
D E
D A
E
Phase
L
J
F G
Note 4
Customer Transformer Primaries
6VM1S (IEC Connector, DPST On/Off Switch, Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
XM & ZM (1-Voltage)
Power On/Off
C E
Neutral
Note 2 Note 1
H
B
D B A
J F
Phase
G
6VM1SC (IEC Connector, DPST On/Off Switch, Selectable Fuseholder, Snap-In)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
XM & ZM (4-Voltage)
120V 100V Power On/Off Note 2 Note 1
C D E C D E F 120V
230V 240V
A A 20V 100V
C
Note 4
K H B
Neutral
D A
E
Phase
L
J
F G
Note 4
Recommended Panel Cutout (Snap-In Only)
0.13 R 3.30 1.145 29.08
Customer Transformer Primaries
Note 1: Note 2: Note 3: Note 4:
Provision for dual fusing (Euro standard) Power on/off switch with suffix "S" only HM models without line-to-ground capacitors Models HM4, FM4, XM4, and ZM4 have added terminals K and L. External switch or jumper must be placed from K to H and L to J. 230V Nomenclature relates to pending European CENELEC agreement.
F
Typical dimensions: Mounting Holes: .155 [3.94] Dia. (2) with .279 [7.09] Dia. x 82 Countersunk. Panel Thickness: .06 - .09 [1.53 -2.29] All mounting holes countersunk.
127
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
Case Styles - Unfiltered Models (cont'd)
6VM2 & 6VM4 (IEC Connector, Voltage Selector,
Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
Case Styles - Filtered Models
3EXM1S & 3EZM1S (IEC Connector, DPST On/Off Switch, Selectable Fuseholder)
G
Thread 6-32 x 1/4 1.13.020 28.7.508
100V 120V 230V 240V
C
1.88.020 47.8.508
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
D B A
E
3.09 Max. 78.49
C E
6VM4C (IEC Connector, Voltage Selector, Selectable
Fuseholder, Snap-In)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
D B A
100V 120V 230V 240V
C
D A
E
3EXM4 & 3EZM4 (IEC Connector, Voltage Selector, Selectable Fuseholder)
G
Thread 6-32 x 1/4 1.13.020 28.7.508 1.88.020 47.8.508 3.09 Max. 78.49
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
6VM4C.ai 6VM2S & 6VM4S (IEC Connector, DPST On/Off Switch,
Voltage Selector, Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
C
100V 120V 230V 240V
C E
D B A
E
D B A
6VM4SC (IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder, Snap-In)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
3EXM4S & 3EZM4S (IEC Connector, DPST On/Off Switch, Voltage Selector, Selectable Fuseholder)
C
G
E
1.88.020 47.8.508
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
Thread 6-32 x 1/4 1.17.020 29.7.508 3.09 Max. 78.49
100V 120V 230V 240V
B A
C E
D B A
128
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
Case Styles - Filtered Models (cont'd)
5EHM1 & 5EFM1 (IEC Connector, Selectable
Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
5EHM4 & 5EFM4 (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
100V 120V 230V 240V
C E
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
C E
D B A
D B A
Power Entry Modules
5EFM1C (IEC Connector, Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
5EFM4C (IEC Connector, Voltage Selector, Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
A D
C
A D C
E
E
5EHM1S & 5EFM1S (IEC Connector, DPST On/Off
Switch, Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
5EHM4S & 5EFM4S (IEC Connector, DPST On/Off
Switch, Voltage Selector, Selectable Fuseholder)
C E
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
100V 120V 230V 240V
C E
D B A
D B A
5EFM1SC (IEC Connector, DPST On/Off Switch,
Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
A D
C
E
Typical dimensions: Torque: 7 in. lb max. Holes: .055 [1.40] Dia. .004 [.10] except solder lug ground tap with wire wrap. Mounting Holes: .155 [3.94] Dia. All parts typical. Note: Mounting holes on tabs are countersunk and take a #6 flathead screw.
129
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
Case Styles - Filtered Models (cont'd)
5EFM4SC (IEC Connector, DPST On/Off Switch, Voltage
Selector, Selectable Fuseholder)
USE ONLY WITH 250V FUSES
DISCONNECT POWER BEFORE REPLACING FUSES
Case Dimensions
Part No. 3EXM1S 3EZM1S 3EXM4 3EZM4 3EXM4S 3EZM4S 5EFM1 5EHM1
E
A (max) 4.17 105.9 3.88 98.6 4.65 118.1 3.39 86.1 2.56 65.0 4.17 105.9 3.34 84.8 3.88 98.6 3.04 77.2 4.65 118.1 3.82 97.0 3.39 86.1 2.56 86.1 4.17 105.9 3.34 84.8 3.88 98.6 3.04 98.6 4.65 118.1 3.82 97.0
B
0.01 0.038
C D E (max) (max) (max) 3.22 81.8 2.92 74.2 3.72 94.5 2.44 62.0 2.44 62.0 3.22 81.8 3.27 83.1 2.92 74.2 2.92 74.2 3.7 94.0 3.7 94.0 2.44 62.0 2.44 62.0 3.22 81.8 3.27 83.1 2.92 74.2 2.92 74.2 3.72 94.5 3.7 94.0 1.72 43.7 1.72 43.7 1.72 43.7 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 2.19 55.6 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8 1.45 36.8
F 3.28 83.8 2.98 75.7 3.76 95.5 2.5 63.5 2.49 63.2 3.28 83.3 3.27 83.1 2.98 75.7 2.97 75.4 3.76 95.5 3.75 95.3 2.5 63.5 2.5 63.2 3.28 83.3 3.27 83.1 2.98 75.7 2.97 75.4 3.76 95.5 3.75 95.3
G 3.3 83.8 2.99 75.9 3.8 96.5 -- -- -- -- -- -- -- --
100V 120V 230V 240V
A D C
5EFM1C 5EFM1S 5EHM1S 5EFM1SC 5EFM4 5EHM4 5EFM4C 5EFM4S 5EHM4S 5EFM4SC
Recommended Panel Cutout
*Blind insert XM and ZM Models only
6VM1
1.88 + .020 47.8 + .508
+ *4S Models 1.17 .020 29.7 + .508 + *1S & 4 models 1.13 .020 28.7 + .508 0.13 R 3.30
Holes (2)
6VM1C 6VM1S
1.145 29.08
.570 14.5
.170 Dia. 4.32 .175 4.45
6VM1SC 6VM2 6VM4 6VM4C 6VM2S 6VM4S 6VM4SC
F B
Note: Snap-in models allow front mount only. XM and ZM models allow back mount only. FM and HM models allow front or back mounting. Accessories for M series include interconnection assembly, medical standoff bracket, voltage selector cards, and insulating shroud. See page 142. All mounting holes countersunk.
1.14 29.0 1.14 29.0 1.14 29.0 1.14 29.0 1.14 -- 29.0 3.62 1.14 91.9 29.0 1.14 -- 29.0 3.32 1.14 84.3 29.0 1.14 -- 29.0 4.1 1.14 104.1 29.0 1.14 -- 29.0 2.84 1.14 72.1 29.0 1.14 -- 29.0 3.62 1.14 91.9 29.0 1.14 -- 29.0 3.32 1.14 84.3 29.0 1.14 -- 29.0 4.1 1.14 104.1 29.0 1.14 -- 29.0
3.62 91.9 3.32 84.3 4.1 104.1 2.84 72.1
130
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com
CORCOM Product Guide Power Entry Module with Optional RFI Power Line Filters for General and Medical Applications (Continued)
M Series
FILTERED MODELS
Part Number 3EXM1S 3EXM4 3EXM4S 3EZM1S 3EZM4 3EZM4S 5EHM1 5EHM1S 5EHM4 5EHM4S 5EFM1 5EFM1C 5EFM1S 5EFM1SC 5EFM4 5EFM4C 5EFM4S 5EFM4SC RFI Current Rating Current Rating @120VAC @250VAC Filter Type (Amps) (Amps) SMPS FCC-B1 3 2 SMPS FCC-B1 3 2 SMPS FCC-B1 2 3 SMPS EN55022-B2 2 3 SMPS EN55022-B2 3 2 SMPS EN55022-B2 3 2 5 4 Medical3 Medical3 5 4 5 4 Medical3 Medical3 5 4 General Purpose 5 4 5 4 General Purpose 5 4 General Purpose General Purpose 5 4 General Purpose 5 4 General Purpose 5 4 5 4 General Purpose General Purpose 5 4 Available Voltage Selection Positions 1 4 4 1 4 4 1 1 4 4 1 1 1 1 4 4 4 4 DPST On/Off Switch * * * * * * * * * * Mounting Style Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Flange Snap-in Flange Snap-in Flange Snap-in Flange Snap-in
Power Entry Modules
* Includes DPST switch
UNFILTERED MODELS
Part Number 6VM1 6VM1C 6VM1S 6VM1SC 6VM2 6VM2S 6VM4 6VM4C 6VM4S 6VM4SC
Current Rating @120VAC (Amps) 6 6 6 6 6 6 6 6 6 6
Current Rating 250VAC (Amps) 6 6 4 4 6 6 6 6 4 4
Available Voltage Selection Position 1 1 1 1 2 2 4 4 4 4
DPST On/Off Switch * * * * *
Mounting Style Flange Snap-in Flange Snap-in Flange Flange Flange Snap-in Flange Snap-in
* Includes DPST switch 1-120V/240V Fixed, 2 - 120/240V Selectable, 4- 100, 120, 230, 240V selectable 1 Emissions filter for switching power supply applications where FCC-B level requirements must be met 2 Emissions filter for switching power supply applications where En5502-B level requirements must be met 3 Medical filter for very low leakage UL544, UL2601 and EN60601 health care applications General purpose filer for susceptibility applications
131
Catalog 1654001 Revised 05-07 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. USA Cust. Svc.: 1-800-468-2023 CORCOM Prods: 1-847-680-7400 Germany: 49-89-6089-0 www.corcom.com www.tycoelectronics.com


▲Up To Search▲   

 
Price & Availability of 5EHM1S

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X